Sam,
Is the switch behind the batteries pushed in? Others have used a thin piece
of cardboard. This is necessary because without the button pressed, Newton
assumes that the batteries are regular alkalines. The % charge the Newton
displays is based on the battery voltage. Alkaline batteries have about 1.5
volts each. NiCd have about 1.2 volts each. So fully charged NiCd "look
like" partially charged alkalines to the Newton.
Allen
-----Original Message-----
From: Samuel Jacobson [mailto:jacobson98_at_earthlink.net]
Sent: Thursday, September 20, 2001 11:16 AM
To: newtontalk_at_newtontalk.net
Subject: Re: [NTLK] Another MP120 Question
Dear All,
I recently picked up some rechargeable 1000 mAH NiCd batteries and, after
charging them for ~17 hours, put them into my MP120. However I noticed that
the unit only listed a 90% charge and, after only ~10 minutes of adding
appointments to my dates the charge had dropped to 80%. At this rate I will
only get a few hours use out the batteries before they need to be
recharged. Is there anything that can be done about this?
Thanks again as I do very much appreciate everyones time and help on all
of my questions.
Respectfully,
Sam
_________________________________________________________________
Always remember, "Ad astra per aspera"...
email:
jacobson98_at_earthlink.net
or
sjacobso_at_chuma.cas.usf.edu
Lab. Telephone (via Dr. Susan Bell): 813-974-5420
SnailMail:
Department of Biology
University of South Florida
SCA 110
4202 East Fowler Avenue
Tampa, Florida, 33620
-- This is the Newtontalk mailinglist - http://www.newtontalk.net To unsubscribe or manage: visit the above link or mailto:newtontalk-request_at_newtontalk.net?Subject=unsubscribe********************************************************************* This footnote confirms that this e-mail message has been scanned for the presence of known computer viruses by the MessageLabs Virus Control Centre. However, it is still recommended that you use local virus scanning software to monitor for the presence of viruses. *********************************************************************
********************************************************************* This footnote confirms that this e-mail message has been scanned for the presence of known computer viruses by the MessageLabs Virus Control Centre. However, it is still recommended that you use local virus scanning software to monitor for the presence of viruses. *********************************************************************
-- This is the Newtontalk mailinglist - http://www.newtontalk.net To unsubscribe or manage: visit the above link or mailto:newtontalk-request_at_newtontalk.net?Subject=unsubscribe
This archive was generated by hypermail 2.1.2 : Wed Oct 03 2001 - 12:02:04 EDT