Re: [NTLK] Correct Thermister

From: Marco Mailand (N_at_abasurf.ch)
Date: Wed Jan 29 2003 - 15:58:38 PST


"Damien Batstone" wrote @ 29.1.2003 16:20 Uhr / <djb_at_er.dtu.dk>:
> Anyone know the correct thermister for the rechargable pack. Daniel
> Padilla used 10 Kohm on his page. Is this right?
Hola,
I've sucessfully used a Farnell type, ordering number 679-446, 10kOhm. This
one is leaded and looks like a small capacitor - pretty much as the original
looks like. Also the temperature characteristic is well matched to the
original one, at least at the 3 temperatures I've checked.

-- 
With best Regards / Viele Gruesse!
Marco Mailand