Re: [NTLK] Newton Messagepad 120 charging

From: Marco Mailand (Newton2k1_at_mac.com)
Date: Thu Nov 22 2001 - 07:46:37 EST


> > orange, but it stays orange for ever it doesn't change to green when it
is
> > charged. ...
> > Also the switch in the battery compartment is pressed down.
> Whether the Charging station is defective, or I would suspect the battery
pack.
I've observed the above mentioned behaviour with an accu pack with only one
defective cell, which is no problem at all with the MP1x0 accu pack.You
should measure the cell voltages if you can and compare them at the end of
charging with the discharged state. I think that only one cell will show a
lower voltage at the end of discharge.

--
With best regards / Viele Gruesse!

Marco Mailand http://slsbd.psi.ch/timing